TW-80 mm2 450/750 V from 16 mm2

Products

TW-80 120 mm2

Nexans ref. P00020269-2

  • Packaging: Cut to length (m)
  • Conductor diameter: 12.8 mm
  • Nominal outer diameter: 16.2 mm
  • Approximate weight: 1143 kg/km

 

TW-80 150 mm2

Nexans ref. P00000106-2

  • Packaging: Cut to length (m)
  • Conductor diameter: 14.2 mm
  • Nominal outer diameter: 18.0 mm
  • Approximate weight: 1406 kg/km

 

TW-80 16 mm2

Nexans ref. P00000172-4

  • Packaging: Cut to length (m)
  • Conductor diameter: 4.6 mm
  • Nominal outer diameter: 6.7 mm
  • Approximate weight: 165 kg/km

 

TW-80 185 mm2

Nexans ref. P00000107-2

  • Packaging: Cut to length (m)
  • Conductor diameter: 15.8 mm
  • Nominal outer diameter: 20.0 mm
  • Approximate weight: 1766 kg/km

 

TW-80 25 mm2

Nexans ref. P00000173-4

  • Packaging: Cut to length (m)
  • Conductor diameter: 5.8 mm
  • Nominal outer diameter: 8.3 mm
  • Approximate weight: 259 kg/km

 

TW-80 50 mm2

Nexans ref. P00000175-4

  • Packaging: Cut to length (m)
  • Conductor diameter: 7.9 mm
  • Nominal outer diameter: 10.8 mm
  • Approximate weight: 467 kg/km

 

TW-80 70 mm2

Nexans ref. P00000176-4

  • Packaging: Cut to length (m)
  • Conductor diameter: 9.5 mm
  • Nominal outer diameter: 12.4 mm
  • Approximate weight: 663 kg/km

 

Description

Description

Standards

  • Product
    IEC 60227-1; IEC 60227-2; IEC 60227-3; IEC 60228; NTP 370.252; NTP-IEC 60228
  • Test
    IEC 60332-1-2; IEC 60811-401; IEC 60811-402; IEC 60811-501; IEC 60811-504; IEC 60811-505; IEC 60811-506; IEC 60811-508; IEC 60811-509; UL 2556

TW-80 mm2 450/750 V from 16 mm2

In fixed installations, in buildings, dry or wet indoor locations. Typically installed in pipe.

BENDING RADIUS WHEN INSTALLED IN L.V.

R=Dxf

R: Bending radius when installed (mm)

D: Diameter over sheath or over insulation (when it has not sheath) (mm)

f: Multiplicative factor; given the following table:

Bending radius factor LV

CALCULATION OF CURRENT CONDITION: BUILDING WIRE L.V.; 80°C

CURRENT CAPACITY VALUES AND CURRENT CALCULATION CONDITIONS BASED ON IEC 60364-5-52:2009 :

TABLE B.52.2 (METHOD A1: Two single-core cables in conduit in a thermally insulated wall).
TABLE B.52.10 (METHOD F: Two single-core cables in the air in flat formation and in contact).
Maximum conductor temperature : 80°C.
Ambient air temperature : 30°C.

The above values were corrected with a correction factor for the operating temperature of 80°C.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Soft copper
Insulating material
PVC
Lead free
Yes
Colour
Customer Request
Conductor flexibility
Class 2 IEC 60228
Conductor shape
Compact stranded

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
450/750 V
Dielectric strength
2.5 kV
Time of application Dielectric strength core to screen DC
5 min.

Usage characteristics

Usage characteristics

Flame retardant
UL 1581 VW1
Oil resistance
Oil resistance II
Maximum operating temperature
80 °C
Overload maximum core temperature
100 °C
Short-circuit max. conductor temperature
160 °C

Resources

Resources

Find a Distributor

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close