- Markets
- Catalogue
- Services
- Tools & Resources
- Downloads
- Company
- Newsroom
-
Nexans Insights
- Nexans Insights
-
Blog Posts
- Overview
- Growing demand for copper and its future
- Electromobility: the road to building an increasingly sustainable transport system
- Guide to Prevent Fires and Accidents at Home (only in Spanish)
- Ten technologies to electrify the future: Electrical and Fire Safety
- Big data & AI
- IoT
- Unveiling innovations transforming the industry
- Transforming buildings industry with 3D printing and modular construction
- The path to effective fire safety in buildings
- Powering the digital change
- Unleashing the power of DC buildings
- Sustainable buildings for a brighter future
- Industry 1, 2, 3, 4... and 5.0
- Nexans copper odyssey
- Search
- Contact us
- Compare
- Sign in
3/0 AWG
3/0 AWG
Premium Nexans Medium Voltage Aluminum Power Cable meets all the requirements of the ICEA S-94-649 Standard
Read moreDescription
Description
Standards
-
ProductASTM B 230; ICEA S-94-649
Ampacity and Reactance Conditions
- Ampacities of Insulated Single Aluminum Conductor Isolated in Air Based on Conductor Temperatures of 90° C and Ambient Air Temperature of 40°C. According to NEC, Table 310.60(C)(70).
- Ampacities of Three Single-Insulated Aluminum Conductors in Underground Electrical Ducts (Three Conductors per Electrical Duct) Based on Ambient Earth Temperature of 20°C, 100% Load Factor, Thermal Resistance (RHO) of 90, Conductor Temperatures of 90°C. According to NEC, Table 310.60(C)(78).
- Reactance Inductive to 90°C, 60Hz, 3 conductors spaced 1 diameter. Trifoil and flat configuration
NOTE:
- The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
- Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantitie.
RECOMMENDATIONS FOR THE SELECTION OF ACCESSORIES AND DUCTS
The technical information presented here is for reference purposes only. Actual dimensions and construction details will only be available with the test reports for each manufacturing order. For the selection of accessories and/or ducts, it is recommended to measure directly on the actual dimensions of the cable using the appropriate methods and instruments. Centelsa by Nexans will not assume any responsibility for the selection of such elements.
Nexans Solar Offer
Solar Offer - Key Insights
Solar Project - Phases
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor material
Stranded aluminum
Conductor shape
Circular compacted
Conductor flexibility
Class B
Insulation
TR-XLPE (Tree-Retardant Cross-linked Polyethylene)
Neutral Type
Concentric Copper Wires, N=1/3
Jacket material
LDPE
Dimensional characteristics
Dimensional characteristics
Conductor cross-section (AWG/KCMIL)
3/0 AWG
Total number of wires
19
Conductor cross-section
85 mm²
Conductor diameter
10.75 mm
Minimum insulation thickness
10.2 mm
Nominal outer diameter
43.47 mm
Approximate weight
1519.89 kg/km
Minimum outer sheath thickness
1.78 mm
Electrical characteristics
Electrical characteristics
Insulation Level
133 %
Maximum rated voltage
35 kV
Dielectric strength core to screen AC
84.0 kV
Time of application Dielectric strength core to screen AC
5 min.
Maximal partial discharge test
5 pC
Max. DC resistance of the conductor at 20°C
0.345 Ohm/km
Max. Electrical Resistance AC 60Hz 90°C
0.443 Ohm/km
Nominal capacitance
126.0 pF/m
Perm current rating in air 40°C
270 A
Permissible current rating buried/duct 20°C - Trefoil formation
200 A
Phase reactance 60 Hz - flat formation
0.196 Ohm/km
Phase reactance 60 Hz - trefoil formation
0.179 Ohm/km
Mechanical characteristics
Mechanical characteristics
Maximum Pull Tension of Conductor
4 kN
Minimum repeated bending diameter
522 mm
Abrasion resistance
Excellent
Usage characteristics
Usage characteristics
Maximum operating temperature
90 °C
Overload maximum core temperature
130 °C
Short-circuit max. conductor temperature
250 °C
U.V resistance
ICEA S-94-649, (720 hours)
Oil resistance
No
Longitudinal water tightness
ICEA T-31-610
RoHS compliant
Yes
Water proof
AD8 according to ABNT NBR 14039
Flame retardant
IEC 60332-1-2
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania