- Markets
- Catalogue
- Services
- Tools & Resources
- Downloads
- Company
- Newsroom
-
Nexans Insights
- Nexans Insights
-
Blog Posts
- Overview
- Growing demand for copper and its future
- Electromobility: the road to building an increasingly sustainable transport system
- Guide to Prevent Fires and Accidents at Home (only in Spanish)
- Ten technologies to electrify the future: Electrical and Fire Safety
- Big data & AI
- IoT
- Unveiling innovations transforming the industry
- Transforming buildings industry with 3D printing and modular construction
- The path to effective fire safety in buildings
- Powering the digital change
- Unleashing the power of DC buildings
- Sustainable buildings for a brighter future
- Industry 1, 2, 3, 4... and 5.0
- Nexans copper odyssey
- Find Distributors
- Search
- Contact us
- Compare
- Sign in
400 mm2
400 mm2
Premium Nexans Medium Voltage Aluminum Power Cable meets all the requirements of the IEC 60502-2 Standard.
Read moreDescription
Description
Standards
-
ProductIEC 60228 Class 2 ; IEC 60502-2
Ampacity and Reactance Conditions
- Ampacities of Three Single-Insulated Aluminum Conductors in Air Based on Conductor Temperatures of 90° C and Ambient Air Temperature of 30°C, trefoil configuration. According to IEC 60502-2, Table B.3.
- Ampacities of Three Single-Insulated Aluminum Conductors Buried direct in the ground, Based on Ambient Earth Temperature of 20°C, Depth of layin of 0.8 m, Thermal resistivity of soil 1.5 K.m/W, Conductor Temperatures of 90°C, screens bonded at both ends According to IEC 60502-2, Table B.3.
- Inductive Reactance to 90°C, 60Hz, 3 conductors spaced 1 diameter. Trifoil and flat configuration.
NOTE:
- The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
- Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantitie.
RECOMMENDATIONS FOR THE SELECTION OF ACCESSORIES AND DUCTS
The technical information presented here is for reference purposes only. Actual dimensions and construction details will only be available with the test reports for each manufacturing order. For the selection of accessories and/or ducts, it is recommended to measure directly on the actual dimensions of the cable using the appropriate methods and instruments. Centelsa by Nexans will not assume any responsibility for the selection of such elements.
Nexans Solar Offer
Solar Offer - Key Insights
Solar Project - Phases
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor material
Stranded aluminum
Conductor shape
Circular compacted
Conductor flexibility
Class 2
Insulation
TR-XLPE (Tree-Retardant Cross-linked Polyethylene)
Screen
Copper wire
Jacket material
LDPE
Dimensional characteristics
Dimensional characteristics
Total number of wires
61
Conductor cross-section
400 mm²
Conductor diameter
23.57 mm
Minimum insulation thickness
7.1 mm
Nominal outer diameter
48.39 mm
Approximate weight
2330.5 kg/km
Minimum outer sheath thickness
1.8 mm
Electrical characteristics
Electrical characteristics
Insulation Level
- %
Maximum operating voltage
18/30(36) kV
Dielectric strength core to screen AC
63.0 kV
Time of application Dielectric strength core to screen AC
5 min.
Maximal partial discharge test
10 pC
Max. DC resistance of the conductor at 20°C
0.077 Ohm/km
Max. Electrical Resistance AC 60Hz 90°C
0.102 Ohm/km
Nominal capacitance
273.1 pF/m
Perm current rating in air 30°C
673 A
Permissible current rating buried/duct 20°C - Trefoil formation
470 A
Phase reactance 60 Hz - flat formation
0.144 Ohm/km
Phase reactance 60 Hz - trefoil formation
0.127 Ohm/km
Mechanical characteristics
Mechanical characteristics
Maximum Pull Tension of Conductor
20 kN
Minimum repeated bending diameter
581 mm
Abrasion resistance
Excellent
Usage characteristics
Usage characteristics
Maximum operating temperature
90 °C
Overload maximum core temperature
130 °C
Short-circuit max. conductor temperature
250 °C
U.V resistance
ICEA S-93-639, (720 hours)
Oil resistance
No
Longitudinal water tightness
ICEA T-31-610
RoHS compliant
Yes
Water proof
AD8 according to ABNT NBR 14039
Flame retardant
IEC 60332-1-2