- Markets
- Catalogue
- Services
- Tools & Resources
- Downloads
- Company
- Newsroom
-
Nexans Insights
- Nexans Insights
-
Blog Posts
- Overview
- Growing demand for copper and its future
- Electromobility: the road to building an increasingly sustainable transport system
- Guide to Prevent Fires and Accidents at Home (only in Spanish)
- Ten technologies to electrify the future: Electrical and Fire Safety
- Big data & AI
- IoT
- Unveiling innovations transforming the industry
- Transforming buildings industry with 3D printing and modular construction
- The path to effective fire safety in buildings
- Powering the digital change
- Unleashing the power of DC buildings
- Sustainable buildings for a brighter future
- Industry 1, 2, 3, 4... and 5.0
- Nexans copper odyssey
- Find Distributors
- Search
- Contact us
- Compare
- Sign in
Cable Premium Nexans Potencia Media Tensión Aluminio XLPE-TR/PE 15kV 133% N=1/3
Cable Premium Nexans Potencia Media Tensión Aluminio XLPE-TR/PE 15kV 133% N=1/3
Premium Nexans Medium Voltage Aluminum Power Cable meets all the requirements of the ICEA S-94-649 Standard.
Read moreDescription
Description
Standards
-
ProductASTM B 230; ICEA S-94-649
PREMIUM SOLAR CABLE
Premium Nexans Medium Voltage Aluminum Power Cable meets all the requirements of the ICEA S-94-649 Standard. It has a 1350 aluminum conductor, concentric stranded with humidity blocking, cross-linked polyethylene (XLPE-TR) insulation, concentric neutral in copper wires, water blocking tapes before and after the neutral wires, Polyethylene jacket, resistant to heat, abrasion and humidity, resistant to solar rays. Compounds free of hazardous substances (RoHS)
Application and Features
Power supply of 15kV Medium Voltage circuits at 133% insulation level, mainly the connection between the feeder transformer and the electrical distribution network. Cables suitable for installation in outdoors exposed to sunlight, underground ducts, directly buried, in dry or wet locations.
Main features:
- Directly buried installation, according to ICEA S-94-649 standard.
- Resistance to solar rays, complying with the test defined in the ICEA S-94-649 standard, exposure to 720 hours.
- Cable designed to be permanently submerged in water according to the condition AD8, according to the test procedure of the NBR 14039 standard.
Construction
1. Conductor: Compacted Aluminum, class B with moisture blocking.
2. Internal semi-conductor: Extruded compound.
3. Insulation: Cross-linked polyethylene XLPE-TR.
4. External semi-conductor: Peelable extruded compound.
These last three components extruded in CV (continuous vulcanization) of triple extrusion in the dry curing process.
5. Concentric Neutral: Made up of copper wires N=1/3, with water blocking tapes before and after the wires.
6. Outer jacket: LDPE compound resistant to heat, abrasion and humidity, resistant to solar rays (SR), black color.
Applicable Standards
ICEA S-94-649, NTC 2186-1.
Certificate
RETIE N° 05196
Operating Temperature
90°C.
Operating Voltage
15 kV.
Identification
Natural insulation color and black external jacket. Sequential length meter by meter with return to zero.
Unit Packaging
500 m or 1000 m reels. Other packaging units available upon request.
Optional Features available upon request:
Insulation XLPE-TR (Tree retardant) compound. External cover HDPE, Halogen-free compound, low smoke emission, flame retardant and UV resistant. Application of additives protection against rodents and termites.
For more information, contact our sales representative.
Ampacity and Reactance Conditions
- Ampacities of Insulated Single Aluminum Conductor Isolated in Air Based on Conductor Temperatures of 90° C and Ambient Air Temperature of 40°C. According to NEC, Table 310.60(C)(70).
- Ampacities of Three Single-Insulated Aluminum Conductors in Underground Electrical Ducts (Three Conductors per Electrical Duct) Based on Ambient Earth Temperature of 20°C, 100% Load Factor, Thermal Resistance (RHO) of 90, Conductor Temperatures of 90°C. According to NEC, Table 310.60(C)(78).
- Reactance Inductive to 90°C, 60Hz, 3 conductors spaced 1 diameter. Trifoil and flat configuration
NOTE:
- The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing practices.
- Other configurations not specified in this catalog may be available under special request and minimum manufacturing quantitie.
RECOMMENDATIONS FOR THE SELECTION OF ACCESSORIES AND DUCTS
The technical information presented here is for reference purposes only. Actual dimensions and construction details will only be available with the test reports for each manufacturing order. For the selection of accessories and/or ducts, it is recommended to measure directly on the actual dimensions of the cable using the appropriate methods and instruments. Centelsa by Nexans will not assume any responsibility for the selection of such elements.
Nexans Solar Offer
Solar Offer - Key Insights
Solar Project - Phases
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania