- Markets
- Catalogue
- Services
- Tools & Resources
- Downloads
- Company
- Newsroom
-
Nexans Insights
- Nexans Insights
-
Blog Posts
- Overview
- Growing demand for copper and its future
- Electromobility: the road to building an increasingly sustainable transport system
- Guide to Prevent Fires and Accidents at Home (only in Spanish)
- Ten technologies to electrify the future: Electrical and Fire Safety
- Big data & AI
- IoT
- Unveiling innovations transforming the industry
- Transforming buildings industry with 3D printing and modular construction
- The path to effective fire safety in buildings
- Powering the digital change
- Unleashing the power of DC buildings
- Sustainable buildings for a brighter future
- Industry 1, 2, 3, 4... and 5.0
- Nexans copper odyssey
- Find Distributors
- Search
- Contact us
- Compare
- Sign in
CAAI 0,6/1 kV AAAC Covered Neutral with Public Lighting
CAAI 0,6/1 kV 1x16+1x16+NA25 mm2
Nexans ref. P00015906-4 - Country ref. 10037283
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 5 mm
- Nominal outer diameter: 17.2 mm
- Approximate weight: 235 kg/km
CAAI 0,6/1 kV 1x25+1x16+NA25mm2
Nexans ref. P00038970-0 - Country ref. 10053440
- Packaging: Drum
- Phase Conductor Diameter: 5.8 mm
- Nominal outer diameter: 18.2 mm
- Approximate weight: 261 kg/km
CAAI 0,6/1 kV 2x16+1x16+NA25 mm2
Nexans ref. P00015907-5 - Country ref. 10037284
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 5 mm
- Nominal outer diameter: 18.6 mm
- Approximate weight: 303 kg/km
CAAI 0,6/1 kV 2x25+1x25+NA25 mm2
Nexans ref. P00033650-0
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 5.8 mm
- Nominal outer diameter: 20.1 mm
- Approximate weight: 385 kg/km
CAAI 0,6/1 kV 3x16+1x16+NA25 mm2
Nexans ref. P00015905-7 - Country ref. 10037280
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 5 mm
- Nominal outer diameter: 20.6 mm
- Approximate weight: 370 kg/km
CAAI 0,6/1 kV 3x25+1x25+NA25 mm2
Nexans ref. P00033651-1 - Country ref. 10050738
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 5.8 mm
- Nominal outer diameter: 22.4 mm
- Approximate weight: 480 kg/km
CAAI 0,6/1 kV 2x25+2x16+NA25 mm2
Nexans ref. P00018963-4 - Country ref. 10042853
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 5.8 mm
- Nominal outer diameter: 22.5 mm
- Approximate weight: 425 kg/km
CAAI 0,6/1 kV 2x25+1x16+NA25 mm2
Nexans ref. P00015909-4 - Country ref. 10037285
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 5.8 mm
- Nominal outer diameter: 22.7 mm
- Approximate weight: 358 kg/km
CAAI 0,6/1 kV 3x25+1x16+NA25 mm2
Nexans ref. P00015879-7 - Country ref. 10037281
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 5.8 mm
- Nominal outer diameter: 22.7 mm
- Approximate weight: 453 kg/km
CAAI 0,6/1 kV 2x35+1x16+NA25 mm2
Nexans ref. P00015910-5 - Country ref. 10037286
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 6.9 mm
- Nominal outer diameter: 24.4 mm
- Approximate weight: 420 kg/km
CAAI 0,6/1 kV 2x35+1x25+NA25 mm2
Nexans ref. P00031981-1
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 6.9 mm
- Nominal outer diameter: 24.4 mm
- Approximate weight: 448 kg/km
CAAI 0,6/1 kV 3x35+1x16+NA25 mm2
Nexans ref. P00015880-7 - Country ref. 10037282
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 6.9 mm
- Nominal outer diameter: 24.4 mm
- Approximate weight: 547 kg/km
CAAI 0,6/1 kV 3x35+1x25+NA25 mm2
Nexans ref. P00024336-3 - Country ref. 10048523
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 6.9 mm
- Nominal outer diameter: 24.4 mm
- Approximate weight: 574 kg/km
CAAI 0,6/1 kV 2x35+2x16+NA25 mm2
Nexans ref. P00020423-3 - Country ref. 10043321
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 6.9 mm
- Nominal outer diameter: 24.7 mm
- Approximate weight: 488 kg/km
CAAI 0,6/1 kV 3x35+1x35+NA25 mm2
Nexans ref. P00020927-2
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 6.9 mm
- Nominal outer diameter: 24.7 mm
- Approximate weight: 606 kg/km
CAAI 0,6/1 kV 3x25+2x16+NA25 mm2
Nexans ref. P00018964-4 - Country ref. 10042850
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 5.8 mm
- Nominal outer diameter: 25.6 mm
- Approximate weight: 520 kg/km
CAAI 0,6/1 kV 3x35+1x25+NA35 mm2
Nexans ref. P00028022-1
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 6.9 mm
- Nominal outer diameter: 25.7 mm
- Approximate weight: 608 kg/km
CAAI 0,6/1 kV 3x35+2x16+NA50 mm2
Nexans ref. P00039693-0 - Country ref. 10054138
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 6.9 mm
- Nominal outer diameter: 25.9 mm
- Approximate weight: 713 kg/km
CAAI 0,6/1 kV 3x35+2x16+NA25 mm2
Nexans ref. P00018965-4 - Country ref. 10042852
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 6.9 mm
- Nominal outer diameter: 27.0 mm
- Approximate weight: 614 kg/km
CAAI 0,6/1 kV 3x35+2x25+NA25 mm2
Nexans ref. P00031984-1
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 6.9 mm
- Nominal outer diameter: 27.0 mm
- Approximate weight: 669 kg/km
CAAI 0,6/1 kV 3x50+1x16+NA35 mm2
Nexans ref. P00015881-6 - Country ref. 10037287
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 8.1 mm
- Nominal outer diameter: 29.0 mm
- Approximate weight: 731 kg/km
CAAI 0,6/1 kV 2x50+1x25+NA35 mm2
Nexans ref. P00031982-3
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 8.1 mm
- Nominal outer diameter: 29.1 mm
- Approximate weight: 583 kg/km
CAAI 0,6/1 kV 3x50+1x25+NA35 mm2
Nexans ref. P00019760-6
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 8.1 mm
- Nominal outer diameter: 29.1 mm
- Approximate weight: 760 kg/km
CAAI 0,6/1 kV 3x50+1x35+NA35 mm2
Nexans ref. P00026901-3
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 8.1 mm
- Nominal outer diameter: 29.1 mm
- Approximate weight: 791 kg/km
CAAI 0,6/1 kV 2x50+2x16+NA50 mm2
Nexans ref. P00020424-4
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 8.1 mm
- Nominal outer diameter: 30.4 mm
- Approximate weight: 688 kg/km
CAAI 0,6/1 kV 3x50+2x25+NA35 mm2
Nexans ref. P00031987-3
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 8.1 mm
- Nominal outer diameter: 31.7 mm
- Approximate weight: 855 kg/km
CAAI 0,6/1 kV 3x70+1x16+NA50 mm2
Nexans ref. P00015911-8 - Country ref. 10037288
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 9.7 mm
- Nominal outer diameter: 34.2 mm
- Approximate weight: 995 kg/km
CAAI 0,6/1 kV 3x70+1x25+NA50 mm2
Nexans ref. P00020310-3 - Country ref. 10042438
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 9.7 mm
- Nominal outer diameter: 34.2 mm
- Approximate weight: 1022 kg/km
CAAI 0,6/1 kV 2x70+1x25+NA50 mm2
Nexans ref. P00031983-1
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 9.8 mm
- Nominal outer diameter: 34.3 mm
- Approximate weight: 786 kg/km
CAAI 0,6/1 kV 3x95+1x16+NA50 mm2
Nexans ref. P00032299-1
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 11.5 mm
- Nominal outer diameter: 37.2 mm
- Approximate weight: 1252 kg/km
CAAI 0,6/1 kV 3x95+1x25+NA50 mm2
Nexans ref. P00034739-1
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 11.5 mm
- Nominal outer diameter: 37.2 mm
- Approximate weight: 1279 kg/km
CAAI 0,6/1 kV 3x70+2x25+NA50 mm2
Nexans ref. P00031988-1
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 9.8 mm
- Nominal outer diameter: 37.9 mm
- Approximate weight: 1127 kg/km
CAAI 0,6/1 kV 3x95+1x16+NA70 mm2
Nexans ref. P00020869-4 - Country ref. 10045225
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 11.5 mm
- Nominal outer diameter: 38.9 mm
- Approximate weight: 1319 kg/km
CAAI 0,6/1 kV 3x95+1x35+NA70 mm2
Nexans ref. P00037015-0 - Country ref. 10051510
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 11.5 mm
- Nominal outer diameter: 38.9 mm
- Approximate weight: 1378 kg/km
CAAI 0,6/1 kV 3x95+2x16+NA50 mm2
Nexans ref. P00020213-5 - Country ref. 10039990
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 11.4 mm
- Nominal outer diameter: 40.1 mm
- Approximate weight: 1305 kg/km
CAAI 0,6/1 kV 3x95+2x25+NA50 mm2
Nexans ref. P00031989-1
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 11.5 mm
- Nominal outer diameter: 40.3 mm
- Approximate weight: 1374 kg/km
CAAI 0,6/1 kV 3x120+1x25+NA50 mm2
Nexans ref. P00027989-1
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 12.8 mm
- Nominal outer diameter: 41.0 mm
- Approximate weight: 1565 kg/km
CAAI 0,6/1 kV 3x120+1x35+NA50 mm2
Nexans ref. P00028028-1
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 12.8 mm
- Nominal outer diameter: 41.0 mm
- Approximate weight: 1596 kg/km
CAAI 0,6/1 kV 3x120+1x16+NA70 mm2
Nexans ref. P00018051-4 - Country ref. 10044628
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 12.8 mm
- Nominal outer diameter: 42.7 mm
- Approximate weight: 1604 kg/km
CAAI 0,6/1 kV 3x120+1x35+NA70 mm2
Nexans ref. P00034651-0
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 12.8 mm
- Nominal outer diameter: 42.7 mm
- Approximate weight: 1663 kg/km
CAAI 0,6/1 kV 3x150+1x16+NA70 mm2
Nexans ref. P00033604-0
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 14.3 mm
- Nominal outer diameter: 45.2 mm
- Approximate weight: 1864 kg/km
CAAI 0,6/1 kV 3x150+1x25+NA70 mm2
Nexans ref. P00034619-1
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 14.3 mm
- Nominal outer diameter: 45.2 mm
- Approximate weight: 1891 kg/km
CAAI 0,6/1 kV 3x120+2x16+NA70 mm2
Nexans ref. P00032927-1
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 12.8 mm
- Nominal outer diameter: 46.1 mm
- Approximate weight: 1672 kg/km
CAAI 0,6/1 kV 3x120+2x35+NA70 mm2
Nexans ref. P00034650-1
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 12.8 mm
- Nominal outer diameter: 46.1 mm
- Approximate weight: 1790 kg/km
CAAI 0,6/1 kV 3x120+2x50+NA70 mm2
Nexans ref. P00028397-3
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 12.8 mm
- Nominal outer diameter: 46.1 mm
- Approximate weight: 1890 kg/km
Description
Description
Application
For urban and rural overhead secundary distribution networks, with voltages up to 1000 V.
STANDARDS
PRODUCT
NTP-IEC 60228; NTP 370.254; NTP 370.258; IEC 60228
TEST
IEC 60811-201; IEC 60811-401; IEC 60811-402; IEC 60811-501;
IEC 60811-502; IEC 60811-507; IEC 60811-511
CONSTRUCTION
1. Conductor: Compact Aluminium 1350, class 2.
2. Insulation: Cross linked polyethylene XLPE.
3. Public lighting: Aluminium 1350 - XLPE.
4. Insulated neutral messenger: AAAC - All Alloy Aluminium 6201 - XLPE.
MAIN CHARACTERISTICS
Decreases energy theft, cross-linked polyethylene allows more current capacity and high insulation resistance, lower inductive reactance than with bare conductors, used in overhead distribution lines. Increased safety due to its mechanical strength and toughness of the insulation. Insulators are not necessary for installation. Resistance to abrasion, weather and sunlight.
CROSS SECTION
From 16 mm2 up to 150 mm2.
MARKING
INDECO BY NEXANS CAAI 0,6/1 kV - (Nb. Cores x Section) + (Nb. conductors x public lighting section) + NA(Neutral messenger section) - Year - Sequential length.
PACKING
Non returnable wooden reels.
COLOUR
Black, see core identification.
PRODUCT STANDARDS
NTP-IEC 60228: Conductors of insulated cables.
NTP 370.254: Cables for overhead distribution networks self-supporting XLPE insulated of rated voltages up to and including 0.6/1 kV.
NTP 370.258: Conductors with aluminum round wires stranded concentrically for overhead networks.
IEC 60228: Conductors of insulated cables.
TESTING STANDARDS
IEC 60811-201: Measurement of insulation thickness.
IEC 60811-401: Thermal ageing methods -Ageing in an air oven.
IEC 60811-402: Water absorption test.
IEC 60811-501: Test for determining the mechanical properties of insulating and sheating.
IEC 60811-502: Shrinkage test for isolations.
IEC 60811-507: Hot elongation test for crosslinked materials.
IEC 60811-511: Measurement of hot melt index of polyethylene compounds.
BENDING RADIUS WHEN INSTALLED
R = f x D
R: Bending radius when installed (mm).
f: Multiplicative factor.
D: Cable nominal outer diameter (mm).
Calculation of Current Condition overhead secondary distribution CAAI
CALCULATION OF CURRENT CONDITION BASED ON ABNT NBR 8182
Maximum conductor temperature : 90°C.
Ambient air temperature : 30°C.
Speed of cross wind: Nula
Intensity of solar radiation: 1000 W/m2
Bundled conductors.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Find a Distributor
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania