CAAI 0.6/1 kV 25 mm2

Description

Description

Application:

For installations of urban and rural connections, with voltages up to 1000 V.

Construction:

1. Conductor: Aluminum 1350, class 2.

2. Insulation: Cross linked polyethylene XLPE.

Main characteristics:

Decreases energy theft, cross-linked polyethylene allows more current capacity and high insulation resistance, lower inductive reactance than with bare conductors, used in overhead distribution lines. Increased safety due to its mechanical strength and toughness of the insulation. Insulators are not necessary for installation. Resistance to abrasion, weather and sunlight.

Cross section:

16 mm2and 25 mm2.

Marking:

INDECO S.A. CAAI 0,6/1 kV - (Section) - Year - Sequential length.

Packing:

Non returnable wooden reels.

Colour:

Black, see core identification.

National standards

NTP-IEC 60228: Conductors of insulated cables.

NTP 370.254: Cables for overhead distribution networks self-supporting XLPE insulated of rated voltages up to and including 0.6/1 kV.

International standards

IEC 60228: Conductors of insulated cables.

IEC 60811-201: Measurement of insulation thickness.

IEC 60811-401: Thermal ageing methods -Ageing in an air oven.

IEC 60811-402: Water absorption test.

IEC 60811-501: Test for determining the mechanical properties of insulating and sheating.

IEC 60811-502: Shrinkage test for isolations.

IEC 60811-507: Hot elongation test for crosslinked materials.

IEC 60811-511: Measurement of hot melt index of polyethylene compounds.

BENDING RADIUS WHEN INSTALLED

R = f x D
R: Bending radius when installed (mm).
f: Multiplicative factor.
D: Cable nominal outer diameter (mm).

Calculation of Current Condition overhead secondary distribution

CALCULATION OF CURRENT CONDITION

Maximum conductor temperature : 90°C.
Ambient air temperature : 30°C.
Speed of cross wind: 2 km/h.
Bundled conductors.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum Alloy 1350
Insulating material
XLPE
Core identification
Rib markings
Conductor flexibility
Class 2 IEC 60228
Conductor shape
Compact stranded

Dimensional characteristics

Dimensional characteristics

Phase Conductor Cross Section
25 mm²
Phase Conductor Diameter
5.8 mm
Minimum insulation thickness
1.14 mm
Nominal outer diameter
8.2 mm
Approximate weight
93 kg/km
Number of aluminium wires
7
Number of cores
1

Electrical characteristics

Electrical characteristics

Max. DC resistance of the conductor at 20°C
1.2 Ohm/km
Nominal capacitance
401.0 pF/m
Permanent current rating, phase conductor in air a 30°C
114 A
Rated Voltage Uo/U (Um)
0,6/1 kV
Dielectric strength
4.0 kV
Time of application Dielectric strength core to screen DC
5 min.

Usage characteristics

Usage characteristics

Bending factor when installed
4 (xD)
U.V resistance
Yes
Maximum operating temperature
90 °C
Overload maximum core temperature
130 °C
Short-circuit max. conductor temperature
250 °C

Resources

Resources

Dealer locator

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close