CAAI 0,6/1 kV AAAC Covered Neutral without Public Lighting

Products

CAAI 0,6/1 kV 1x16+NA25 mm2

Nexans ref. P00015875-5 - Country ref. 10037273

  • Packaging: Cut to length (m)
  • Phase Conductor Diameter: 5 mm
  • Nominal outer diameter: 16.2 mm
  • Approximate weight: 168 kg/km

 

CAAI 0,6/1 kV 1x25+NA25 mm2

Nexans ref. P00015876-5 - Country ref. 10037274

  • Packaging: Cut to length (m)
  • Phase Conductor Diameter: 5.8 mm
  • Nominal outer diameter: 17.0 mm
  • Approximate weight: 195 kg/km

 

CAAI 0,6/1 kV 1x70+NA50 mm2

Nexans ref. P00034652-0

  • Packaging: Cut to length (m)
  • Phase Conductor Diameter: 9.8 mm
  • Nominal outer diameter: 25.3 mm
  • Approximate weight: 445 kg/km

 

CAAI 0,6/1 kV 2x16+NA25 mm2

Nexans ref. P00015900-5 - Country ref. 10037242

  • Packaging: Cut to length (m)
  • Phase Conductor Diameter: 5 mm
  • Nominal outer diameter: 17.2 mm
  • Approximate weight: 235 kg/km

 

CAAI 0,6/1 kV 2x25+NA25 mm2

Nexans ref. P00015902-5 - Country ref. 10037275

  • Packaging: Cut to length (m)
  • Phase Conductor Diameter: 5.8 mm
  • Nominal outer diameter: 18.2 mm
  • Approximate weight: 290 kg/km

 

CAAI 0,6/1 kV 2x35+NA25 mm2

Nexans ref. P00015903-6 - Country ref. 10037276

  • Packaging: Cut to length (m)
  • Phase Conductor Diameter: 6.9 mm
  • Nominal outer diameter: 19.7 mm
  • Approximate weight: 353 kg/km

 

CAAI 0,6/1 kV 2x35+NA50 mm2

Nexans ref. P00019666-2

  • Packaging: Cut to length (m)
  • Phase Conductor Diameter: 6.9 mm
  • Nominal outer diameter: 22.8 mm
  • Approximate weight: 452 kg/km

 

CAAI 0,6/1 kV 2x50+NA35 mm2

Nexans ref. P00019411-3

  • Packaging: Cut to length (m)
  • Phase Conductor Diameter: 8.1 mm
  • Nominal outer diameter: 23.7 mm
  • Approximate weight: 488 kg/km

 

CAAI 0,6/1 kV 2x50+NA50 mm2

Nexans ref. P00019668-3

  • Packaging: Cut to length (m)
  • Phase Conductor Diameter: 8.1 mm
  • Nominal outer diameter: 25.3 mm
  • Approximate weight: 553 kg/km

 

CAAI 0,6/1 kV 2x70+NA50 mm2

Nexans ref. P00020878-2

  • Packaging: Drum (m)
  • Phase Conductor Diameter: 9.8 mm
  • Nominal outer diameter: 27.7 mm
  • Approximate weight: 691 kg/km

 

CAAI 0,6/1 kV 3x120+NA70 mm2

Nexans ref. P00017153-7 - Country ref. 10039474

  • Phase Conductor Diameter: 12.8 mm
  • Nominal outer diameter: 39.7 mm
  • Approximate weight: 1537 kg/km

 

CAAI 0,6/1 kV 3x150+NA70 mm2

Nexans ref. P00034620-1 - Country ref. 10054768

  • Packaging: Cut to length (m)
  • Phase Conductor Diameter: 14.3 mm
  • Nominal outer diameter: 42.5 mm
  • Approximate weight: 1796 kg/km

 

CAAI 0,6/1 kV 3x16+NA25 mm2

Nexans ref. P00015878-4 - Country ref. 10046885

  • Packaging: Cut to length (m)
  • Phase Conductor Diameter: 5 mm
  • Nominal outer diameter: 18.6 mm
  • Approximate weight: 303 kg/km

 

CAAI 0,6/1 kV 3x185+NA50 mm2

Nexans ref. P00031887-2 - Country ref. 10052233

  • Packaging: Cut to length (m)
  • Phase Conductor Diameter: 16 mm
  • Nominal outer diameter: 44.9 mm
  • Approximate weight: 2072 kg/km

 

CAAI 0,6/1 kV 3x240+NA50mm2

Nexans ref. P00025621-2 - Country ref. 10052234

  • Packaging: Cut to length (m)
  • Phase Conductor Diameter: 18.4 mm
  • Nominal outer diameter: 49.3 mm
  • Approximate weight: 2589 kg/km

 

CAAI 0,6/1 kV 3x25+NA25 mm2

Nexans ref. P00015877-5 - Country ref. 10037278

  • Packaging: Cut to length (m)
  • Phase Conductor Diameter: 5.8 mm
  • Nominal outer diameter: 20.1 mm
  • Approximate weight: 385 kg/km

 

CAAI 0,6/1 kV 3x25+NA35mm2

Nexans ref. P00029784-1

  • Packaging: Cut to length (m)
  • Phase Conductor Diameter: 5.8 mm
  • Nominal outer diameter: 20.7 mm
  • Approximate weight: 419 kg/km

 

CAAI 0,6/1 kV 3x35+NA25 mm2

Nexans ref. P00015904-6 - Country ref. 10037279

  • Packaging: Cut to length (m)
  • Phase Conductor Diameter: 6.9 mm
  • Nominal outer diameter: 22.1 mm
  • Approximate weight: 479 kg/km

 

CAAI 0,6/1 kV 3x35+NA50mm2

Nexans ref. P00013485-2

  • Packaging: Cut to length (m)
  • Phase Conductor Diameter: 6.9 mm
  • Nominal outer diameter: 24.0 mm
  • Approximate weight: 578 kg/km

 

CAAI 0,6/1 kV 3x50+NA35mm2

Nexans ref. P00020772-4 - Country ref. 10045228

  • Packaging: Cut to length (m)
  • Phase Conductor Diameter: 8.1 mm
  • Nominal outer diameter: 26.7 mm
  • Approximate weight: 665 kg/km

 

CAAI 0,6/1 kV 3x70+NA50mm2

Nexans ref. P00023276-3 - Country ref. 10045227

  • Packaging: Cut to length (m)
  • Phase Conductor Diameter: 9.8 mm
  • Nominal outer diameter: 31.1 mm
  • Approximate weight: 937 kg/km

 

CAAI 0,6/1 kV 3x70+NA70 mm2

Nexans ref. P00019022-2

  • Packaging: Cut to length (m)
  • Phase Conductor Diameter: 9.8 mm
  • Nominal outer diameter: 32.0 mm
  • Approximate weight: 1004 kg/km

 

CAAI 0,6/1 kV 3x95+NA50 mm2

Nexans ref. P00019078-2

  • Packaging: Cut to length (m)
  • Phase Conductor Diameter: 11.5 mm
  • Nominal outer diameter: 34.4 mm
  • Approximate weight: 1185 kg/km

 

CAAI 0,6/1 kV 3x95+NA70 mm2

Nexans ref. P00019038-5 - Country ref. 10045226

  • Packaging: Cut to length (m)
  • Phase Conductor Diameter: 11.4 mm
  • Nominal outer diameter: 35.1 mm
  • Approximate weight: 1237 kg/km

 

Description

Description

Application

For urban and rural overhead secundary distribution networks, with voltages up to 1000 V.

STANDARDS

PRODUCT

NTP-IEC 60228; NTP 370.254; NTP 370.258; IEC 60228

TEST

IEC 60811-201; IEC 60811-401; IEC 60811-402; IEC 60811-501;
IEC 60811-502; IEC 60811-507; IEC 60811-511

CONSTRUCTION

1. Conductor: Aluminium 1350, class 2.

2. Insulation: Cross linked polyethylene XLPE.

3. Insulated neutral messenger: AAAC - All Alloy Aluminium 6201 - XLPE.

MAIN CHARACTERISTICS

Decreases energy theft, cross-linked polyethylene allows more current capacity and high insulation resistance, lower inductive reactance than with bare conductors, used in overhead distribution lines. Increased safety due to its mechanical strength and toughness of the insulation. Insulators are not necessary for installation. Resistance to abrasion, weather and sunlight.

CROSS SECTION

From 16 mm2 up to 240 mm2.

MARKING

INDECO BY NEXANS CAAI 0,6/1 kV - (Nb. cores x section) + NA (insul. neutral mesen. section) - Year - Sequential length.

PACKING

Non returnable wooden reels.

COLOUR

Black, see core identification.

PRODUCT STANDARDS

NTP-IEC 60228: Conductors of insulated cables.

NTP 370.254: Cables for overhead distribution networks self-supporting XLPE insulated of rated voltages up to and including 0.6/1 kV.

NTP 370.258: Conductors with aluminum round wires stranded concentrically for overhead networks.

IEC 60228: Conductors of insulated cables.

TESTING STANDARDS

IEC 60811-201: Measurement of insulation thickness.

IEC 60811-401: Thermal ageing methods. Ageing in an air oven.

IEC 60811-402: Water absorption test.

IEC 60811-501: Test for determining the mechanical properties of insulating and sheating.

IEC 60811-502: Shrinkage test for isolations.

IEC 60811-507: Hot elongation test for crosslinked materials.

IEC 60811-511: Measurement of hot melt index of polyethylene compounds.

BENDING RADIUS WHEN INSTALLED

R = f x D
R: Bending radius when installed (mm).
f: Multiplicative factor.
D: Cable nominal outer diameter (mm).

Calculation of Current Condition overhead secondary distribution CAAI

CALCULATION OF CURRENT CONDITION BASED ON ABNT NBR 8182

Maximum conductor temperature : 90°C.
Ambient air temperature : 30°C.
Speed of cross wind: Nula
Intensity of solar radiation: 1000 W/m2
Bundled conductors.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum Alloy 1350
Insulating material
XLPE
Core identification
Rib markings
Neutral messenger
AAAC - All Alloy Aluminium Conductor
Conductor flexibility
Class 2 IEC 60228
Conductor shape
Compact stranded

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV
Dielectric strength
4.0 kV
Time of application Dielectric strength core to screen AC
5 min.

Usage characteristics

Usage characteristics

Bending factor when installed
4 (xD)
U.V resistance
Yes
Maximum operating temperature
90 °C
Overload maximum core temperature
130 °C
Short-circuit max. conductor temperature
250 °C

Resources

Resources

Find a Distributor

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close