NYY(80°) 0,6/1 kV Double or Triple

Products

NYY(80°) 0,6/1 kV 2-1x6 mm2

Nexans ref. P00039373-0 - Country ref. 10053815

  • Packaging: Cut to length (m)
  • Type of conductor: Class 2
  • Sheath colour: Individual sheath Black-Red
  • Approximate weight: 190 kg/km
  • Perm. current rating in air 30°C - flat formation: 53 A
  • Perm. current rating in air 30°C - trefoil formation: - A

 

NYY(80°) 0,6/1 kV 3-1x6 mm2

Nexans ref. P00007971-8 - Country ref. 10001092

  • Packaging: Cut to length (m)
  • Type of conductor: Class 1
  • Sheath colour: Individual sheath White-Black-Red
  • Approximate weight: 280 kg/km
  • Perm. current rating in air 30°C - flat formation: 50 A
  • Perm. current rating in air 30°C - trefoil formation: 47 A

 

NYY(80°) 0,6/1 kV 3-1x10 mm2

Nexans ref. P00008462-12 - Country ref. 10001093

  • Packaging: Cut to length (m)
  • Type of conductor: Class 1
  • Sheath colour: Individual sheath White-Black-Red
  • Approximate weight: 406 kg/km
  • Perm. current rating in air 30°C - flat formation: 69 A
  • Perm. current rating in air 30°C - trefoil formation: 66 A

 

NYY(80°) 0,6/1 kV 3-1x10 mm2

Nexans ref. P00039369-2 - Country ref. 10053816

  • Packaging: Cut to length (m)
  • Type of conductor: Class 2
  • Sheath colour: Individual Sheath Red-Black-Blue
  • Approximate weight: 411 kg/km
  • Perm. current rating in air 30°C - flat formation: 69 A
  • Perm. current rating in air 30°C - trefoil formation: 66 A

 

NYY(80°) 0,6/1 kV 3-1x10 mm2

Nexans ref. P00040248-0 - Country ref. 10054733

  • Packaging: Cut to length
  • Type of conductor: Class 2
  • Sheath colour: Individual sheath White-Black-Red
  • Approximate weight: 411 kg/km
  • Perm. current rating in air 30°C - flat formation: 69 A
  • Perm. current rating in air 30°C - trefoil formation: 66 A

 

NYY(80°) 0,6/1 kV 3-1x16 mm2

Nexans ref. P00001440-10 - Country ref. 10001096

  • Packaging: Cut to length (m)
  • Type of conductor: Class 2
  • Sheath colour: Individual sheath White-Black-Red
  • Approximate weight: 591 kg/km
  • Perm. current rating in air 30°C - flat formation: 94 A
  • Perm. current rating in air 30°C - trefoil formation: 90 A

 

NYY(80°) 0,6/1 kV 3-1x25 mm2

Nexans ref. P00001625-11 - Country ref. 10001099

  • Packaging: Cut to length (m)
  • Type of conductor: Class 2
  • Sheath colour: Individual sheath White-Black-Red
  • Approximate weight: 894 kg/km
  • Perm. current rating in air 30°C - flat formation: 125 A
  • Perm. current rating in air 30°C - trefoil formation: 121 A

 

NYY(80°) 0,6/1 kV 3-1x35 mm2

Nexans ref. P00001634-10 - Country ref. 10001101

  • Packaging: Cut to length (m)
  • Type of conductor: Class 2
  • Sheath colour: Individual sheath White-Black-Red
  • Approximate weight: 1169 kg/km
  • Perm. current rating in air 30°C - flat formation: 157 A
  • Perm. current rating in air 30°C - trefoil formation: 151 A

 

NYY(80°) 0,6/1 kV 3-1x50 mm2

Nexans ref. P00039368-0 - Country ref. 10053813

  • Packaging: Cut to length (m)
  • Type of conductor: Class 2
  • Sheath colour: Individual Sheath Red-Black-Blue
  • Approximate weight: 1545 kg/km
  • Perm. current rating in air 30°C - flat formation: 191 A
  • Perm. current rating in air 30°C - trefoil formation: 184 A

 

NYY(80°) 0,6/1 kV 3-1x50 mm2

Nexans ref. P00001641-9 - Country ref. 10001102

  • Packaging: Cut to length (m)
  • Type of conductor: Class 2
  • Sheath colour: Individual sheath White-Black-Red
  • Approximate weight: 1551 kg/km
  • Perm. current rating in air 30°C - flat formation: 191 A
  • Perm. current rating in air 30°C - trefoil formation: 184 A

 

NYY(80°) 0,6/1 kV 3-1x70 mm2

Nexans ref. P00001627-11 - Country ref. 10001103

  • Packaging: Cut to length (m)
  • Type of conductor: Class 2
  • Sheath colour: Individual sheath White-Black-Red
  • Approximate weight: 2150 kg/km
  • Perm. current rating in air 30°C - flat formation: 248 A
  • Perm. current rating in air 30°C - trefoil formation: 238 A

 

NYY(80°) 0,6/1 kV 3-1x70 mm2

Nexans ref. P00039367-0 - Country ref. 10053812

  • Packaging: Cut to length (m)
  • Type of conductor: Class 2
  • Sheath colour: Individual Sheath Red-Black-Blue
  • Approximate weight: 2150 kg/km
  • Perm. current rating in air 30°C - flat formation: 248 A
  • Perm. current rating in air 30°C - trefoil formation: 238 A

 

NYY(80°) 0,6/1 kV 3-1x95 mm2

Nexans ref. P00001623-8 - Country ref. 10001104

  • Packaging: Cut to length (m)
  • Type of conductor: Class 2
  • Sheath colour: Individual sheath White-Black-Red
  • Approximate weight: 2952 kg/km
  • Perm. current rating in air 30°C - flat formation: 303 A
  • Perm. current rating in air 30°C - trefoil formation: 290 A

 

NYY(80°) 0,6/1 kV 3-1x120 mm2

Nexans ref. P00001591-11 - Country ref. 10001094

  • Packaging: Cut to length (m)
  • Type of conductor: Class 2
  • Sheath colour: Individual sheath White-Black-Red
  • Approximate weight: 3688 kg/km
  • Perm. current rating in air 30°C - flat formation: 353 A
  • Perm. current rating in air 30°C - trefoil formation: 339 A

 

NYY(80°) 0,6/1 kV 3-1x150 mm2

Nexans ref. P00001631-11 - Country ref. 10001095

  • Packaging: Cut to length (m)
  • Type of conductor: Class 2
  • Sheath colour: Individual sheath White-Black-Red
  • Approximate weight: 4506 kg/km
  • Perm. current rating in air 30°C - flat formation: 409 A
  • Perm. current rating in air 30°C - trefoil formation: 392 A

 

NYY(80°) 0,6/1 kV 3-1x185 mm2

Nexans ref. P00001632-9 - Country ref. 10001097

  • Packaging: Cut to length (m)
  • Type of conductor: Class 2
  • Sheath colour: Individual sheath White-Black-Red
  • Approximate weight: 5634 kg/km
  • Perm. current rating in air 30°C - flat formation: 470 A
  • Perm. current rating in air 30°C - trefoil formation: 450 A

 

NYY(80°) 0,6/1 kV 3-1x240 mm2

Nexans ref. P00001633-7 - Country ref. 10001098

  • Packaging: Cut to length (m)
  • Type of conductor: Class 2
  • Sheath colour: Individual sheath White-Black-Red
  • Approximate weight: 7294 kg/km
  • Perm. current rating in air 30°C - flat formation: 558 A
  • Perm. current rating in air 30°C - trefoil formation: 534 A

 

NYY(80°) 0,6/1 kV 3-1x300 mm2

Nexans ref. P00001624-9 - Country ref. 10001100

  • Packaging: Cut to length (m)
  • Type of conductor: Class 2
  • Sheath colour: Individual sheath White-Black-Red
  • Approximate weight: 9096 kg/km
  • Perm. current rating in air 30°C - flat formation: 646 A
  • Perm. current rating in air 30°C - trefoil formation: 617 A

 

NYY(80°) 0,6/1 kV 3-1x400 mm2

Nexans ref. P00001635-3 - Country ref. 10043199

  • Packaging: Cut to length (m)
  • Type of conductor: Class 2
  • Sheath colour: Individual sheath White-Black-Red
  • Approximate weight: 11830 kg/km
  • Perm. current rating in air 30°C - flat formation: 758 A
  • Perm. current rating in air 30°C - trefoil formation: 722 A

 

NYY(80°) 0,6/1 kV 3-1x500 mm2

Nexans ref. P00001626-3 - Country ref. 10047088

  • Packaging: Cut to length (m)
  • Type of conductor: Class 2
  • Sheath colour: Individual sheath White-Black-Red
  • Approximate weight: 14933 kg/km
  • Perm. current rating in air 30°C - flat formation: 868 A
  • Perm. current rating in air 30°C - trefoil formation: 824 A

 

Description

Description

Application:

General use as power cable. In low voltage distribution networks, industrial installations, buildings and operating centers. For fixed installations, in indoor areas (trays, ducts), in underground ducts or buried direct in ground, in dry or wet locations.

STANDARDS

PRODUCT

NTP-IEC 60228; NTP-IEC 60502-1; IEC 60228; IEC 60502-1

TEST

IEC 60332-1-2; UL 2556; IEC 60811-401; IEC 60811-402; IEC 60811-501; IEC 60811-504; 
IEC 60811-505; IEC 60811-506; IEC 60811-508; IEC 60811-509; ICEA S-95-658 

CONSTRUCTION

1. Conductor: Soft copper, class 1 or class 2.

2. Insulation: Compound polyvinyl chloride PVC.

3. Outer sheath: Compound polyvinyl chloride PVC.

4. Tape: Polyester tape.

MAIN CHARACTERISTICS

Good electrical and mechanical properties. The PVC outer sheath provides an adequate resistance to grease, oils and abrasion. better dissipation of heat allowing a higher current capacity. Flame retardant.

CROSS SECTION

From 6 mm2 up to 500 mm2.

MARKING

INDECO BY NEXANS NYY(80º) 0,6/1 kV - Section - Year - Sequential length.

PACKING

Non returnable wooden reels.

COLOUR

Insulation: White.

Outer sheath: Black and white or Black, red and white or Black, red, blue.

PRODUCT STANDARDS

NTP-IEC 60228: Conductors of insulated cables.

NTP-IEC 60502-1: Power cables with extruded insulation and their accessories for rated voltages from 1 kV and 3 kV.

TESTING STANDARDS

IEC 60228: Conductors of insulated cables.

IEC 60502-1: Power cables with extruded insulation and their accessories for rated voltages from 1 kV and 3 kV.

IEC 60332-1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame.

UL 2556: Wire and Cable Test Methods. Section 9.3: FT1 (Vertical-Specimen) Flame Test.

IEC 60811-401: Thermal ageing methods. Ageing in an air oven.

IEC 60811-402: Water absorption tests.

IEC 60811-501: Test for determining the mechanical properties.

IEC 60811-504: Bending test at low temperature for insulation and sheaths.

IEC 60811-505: Elongation at low temperature for insulations and sheaths.

IEC 60811-506: Impact test at low temperature for insulations and sheaths.

IEC 60811-508: Pressure test at high temperature for insulation and sheaths.

IEC 60811-509: Test for resistance of insulations and sheaths to cracking.

ICEA S-95-658: Power cables rated 2000 volts or less for the distribution of electrical energy. Section 6.4.2: Oil: Oil Immersion Test.

UL 2556: Wire and Cable Test Methods. Section 4.2.8.5: Carbon-Arc and Xenon-Arc Tests- Sunlight resistance.

Calculation of Current Condition: Copper Conductor Double or Triple L.V.; 80°C

CURRENT CAPACITY VALUES AND CURRENT CALCULATION CONDITIONS BASED ON IEC 60364-5-52:2009 :

TABLE B.52.4 (METHOD D1: Buried ducts in contact).
TABLE B.52.4 (METHOD D2: Buried in contact).
TABLE B.52.10 (METHOD F: Air in flat formation and in contact).
TABLE B.52.10 (METHOD F: Air in tringular formation).

The cited values ​​were corrected with a correction factor for the maximum conductor temperature at 80°C.
Maximum conductor temperature : 80°C.
Ambient air temperature : 30°C.
Ground temperature : 20°C.
Depth of laying up to: 0,7 m.
Thermal resistivity of soil : 2,5 K.m/W.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Soft copper
Insulating material
PVC
Individual sheath
PVC
Lead free
Yes
Conductor flexibility
Class 1 & Class 2 IEC 60228

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV
Dielectric strength
3.5 kV
Time of application Dielectric strength core to screen AC
5 min.

Usage characteristics

Usage characteristics

Flame retardant
IEC 60332-1-2; FT1
Oil resistance
ICEA S-95-658
U.V resistance
UL 2556 - Sunlight Resistance
Maximum operating temperature
80 °C
Overload maximum core temperature
100 °C
Short-circuit max. conductor temperature
160 °C

Resources

Resources

Find a Distributor

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close