NPT 0,6/1 kV; AWG; with insulated ground conductor

Products

NPT 0,6/1 kV 3x10+1x10AWG

Nexans ref. P00010920-9 - Country ref. 10000807

  • Conductor flexibility: Class 5
  • Insulation colour: White + Black + Red + yellow
  • Number of cores: 3
  • Conductor cross-section (AWG/KCMIL): 10 AWG
  • Conductor diameter: 2.9 mm
  • Minimum insulation thickness: 1.0 mm
  • Ground Conductor cross-section (AWG): 10
  • Minimum outer sheath thickness: 1.2 mm
  • Diameter over Sheath: 14.9 mm
  • Approximate weight: 385 kg/km

 

NPT 0,6/1 kV 3x8+1x8 AWG

Nexans ref. P00010921-9 - Country ref. 10000805

  • Conductor flexibility: Class 5
  • Insulation colour: White + Black + Red + yellow
  • Number of cores: 3
  • Conductor cross-section (AWG/KCMIL): 8 AWG
  • Conductor diameter: 3.9 mm
  • Minimum insulation thickness: 1.0 mm
  • Ground Conductor cross-section (AWG): 8
  • Minimum outer sheath thickness: 1.2 mm
  • Diameter over Sheath: 17.3 mm
  • Approximate weight: 554 kg/km

 

NPT 0,6/1 kV 3x6+1x6 AWG

Nexans ref. P00001346-8 - Country ref. 10000804

  • Conductor flexibility: Class 5
  • Insulation colour: White + Black + Red + yellow
  • Number of cores: 3
  • Conductor cross-section (AWG/KCMIL): 6 AWG
  • Conductor diameter: 4.9 mm
  • Minimum insulation thickness: 1.0 mm
  • Ground Conductor cross-section (AWG): 6
  • Minimum outer sheath thickness: 1.2 mm
  • Diameter over Sheath: 19.7 mm
  • Approximate weight: 790 kg/km

 

NPT 0,6/1 kV 3x4+1x4 AWG

Nexans ref. P00001345-8 - Country ref. 10000803

  • Conductor flexibility: Class 5
  • Insulation colour: White + Black + Red + yellow
  • Number of cores: 3
  • Conductor cross-section (AWG/KCMIL): 4 AWG
  • Conductor diameter: 6.2 mm
  • Minimum insulation thickness: 1.2 mm
  • Ground Conductor cross-section (AWG): 4
  • Minimum outer sheath thickness: 1.2 mm
  • Diameter over Sheath: 24 mm
  • Approximate weight: 1217 kg/km

 

NPT 0,6/1 kV 3x2+1x2 AWG

Nexans ref. P00001344-8 - Country ref. 10000802

  • Conductor flexibility: Class 5
  • Insulation colour: White + Black + Red + yellow
  • Number of cores: 3
  • Conductor cross-section (AWG/KCMIL): 2 AWG
  • Conductor diameter: 7.9 mm
  • Minimum insulation thickness: 1.2 mm
  • Ground Conductor cross-section (AWG): 2
  • Minimum outer sheath thickness: 1.2 mm
  • Diameter over Sheath: 28.3 mm
  • Approximate weight: 1816 kg/km

 

NPT 0,6/1 kV 3x1/0+1x1/0 AWG

Nexans ref. P00001348-4 - Country ref. 10043636

  • Conductor flexibility: Class 6
  • Insulation colour: White + Black + Red + yellow
  • Number of cores: 3
  • Conductor cross-section (AWG/KCMIL): 1/0 AWG
  • Conductor diameter: 9.9 mm
  • Minimum insulation thickness: 1.4 mm
  • Ground Conductor cross-section (AWG): 1/0
  • Minimum outer sheath thickness: 1.5 mm
  • Diameter over Sheath: 34.6 mm
  • Approximate weight: 2754 kg/km

 

NPT 0,6/1 kV 3x3/0+1x3/0 AWG

Nexans ref. P00010923-2

  • Conductor flexibility: Class 6
  • Insulation colour: White + Black + Red + yellow
  • Number of cores: 3
  • Conductor cross-section (AWG/KCMIL): 3/0 AWG
  • Conductor diameter: 12.6 mm
  • Minimum insulation thickness: 1.6 mm
  • Ground Conductor cross-section (AWG): 3/0
  • Minimum outer sheath thickness: 1.7 mm
  • Diameter over Sheath: 42.8 mm
  • Approximate weight: 4339 kg/km

 

NPT 0,6/1 kV 4x8+1x8 AWG

Nexans ref. P00029072-2

  • Conductor flexibility: Class 5
  • Insulation colour: White + Black + Red + Blue + yellow
  • Number of cores: 4
  • Conductor cross-section (AWG/KCMIL): 8 AWG
  • Conductor diameter: 3.9 mm
  • Minimum insulation thickness: 1.0 mm
  • Ground Conductor cross-section (AWG): 8
  • Minimum outer sheath thickness: 1.2 mm
  • Diameter over Sheath: 19 mm
  • Approximate weight: 684 kg/km

 

NPT 0,6/1 kV 4x2+1x2 AWG

Nexans ref. P00004412-2

  • Conductor flexibility: Class 5
  • Insulation colour: White + Black + Red + yellow
  • Number of cores: 4
  • Conductor cross-section (AWG/KCMIL): 2 AWG
  • Conductor diameter: 7.9 mm
  • Minimum insulation thickness: 1.2 mm
  • Ground Conductor cross-section (AWG): 2
  • Minimum outer sheath thickness: 1.4 mm
  • Diameter over Sheath: 31.4 mm
  • Approximate weight: 2270 kg/km

 

NPT 0,6/1 kV 4x2/0+1x2/0 AWG

Nexans ref. P00029746-1

  • Conductor flexibility: Class 6
  • Insulation colour: White + Black + Red + Blue + yellow
  • Number of cores: 4
  • Conductor cross-section (AWG/KCMIL): 2/0 AWG
  • Conductor diameter: 11.1 mm
  • Minimum insulation thickness: 1.4 mm
  • Ground Conductor cross-section (AWG): 2/0
  • Minimum outer sheath thickness: 1.6 mm
  • Diameter over Sheath: 41.8 mm
  • Approximate weight: 4236 kg/km

 

Description

Description

Standards

  • International
    IEC 60228; IEC 60332-1-2; IEC 60502-1; IEC 60811-401; IEC 60811-402; IEC 60811-501; IEC 60811-504; IEC 60811-505; IEC 60811-506; IEC 60811-508; IEC 60811-509
  • National
    NTP-IEC 60228; NTP-IEC 60502-1; UL 2556

 

Application:

In apparatus or equipment subject to movement, winding or vibrations and in all type of mobile installations.

 

Construction:

1. Conductor: Flexible copper, class 5 or 6.

2. Insulation: Compound polyvinyl chloride PVC.

3. Insulated grounding conductor: Flexible copper, class 5 or 6 - Compound polyvinyl chloride PVC.

4. Filler: Compound polyvinyl chloride PVC flexible.

5. Outer sheath: Compound polyvinyl chloride PVC flexible.

 

Main characteristics:

Great flexibility, compact termination, resistance to abrasion and moisture, adequate resistance to oils. Flame retardant.

Gauge:

From 10 AWG up to 3/0 AWG.

Marking:

INDECO S.A. NPT 0,6/1 kV - (Nb. Cores x Section) + (Ground Cond. Section) - FB - Year - Sequencial length.

Packing:

Non returnable wooden reels.

Colour:

Insulation: See insulation colour.

Outer sheath: Black.

 

National standards

NTP-IEC 60228: Conductors of insulated cables.

NTP-IEC 60502-1: Power cables with extruded insulation and their accessories for rated voltages from 1 kV and 3 kV.

International standards

IEC 60228: Conductors of insulated cables.

IEC 60502-1: Power cables with extruded insulation and their accessories for rated voltages from 1 kV and 3 kV.

IEC 60332-1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame.

UL 2556: Wire and Cable Test Methods. Section 9.3: FT1 (Vertical-Specimen) Flame Test.

IEC 60811-401: Thermal ageing methods. Ageing in an air oven.

IEC 60811-402: Water absorption test.

IEC 60811-501: Tests for determining the mechanical properties of insulating and sheating compounds.

IEC 60811-504: Bending test at low temperature for insulation and sheaths.

IEC 60811-505: Elongation at low temperature for insulations and sheaths.

IEC 60811-506: Impact test at low temperature for insulations and sheaths.

IEC 60811-508: Pressure test at high temperature for insulations and sheaths.

IEC 60811-509: Test for resistance of insulations and sheaths to cracking (heat shock test).

Calculation of Current Condition NPT

CALCULATION OF CURRENT CONDITION

Current capacity where the fourth (4th) conductor is a neutral of a balanced 3 phase of a 4 wire system.

Maximum conductor temperature : 80°C.
Ambient air temperature : 30°C.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Soft copper
Insulating material
PVC
Outer sheath
PVC Flexible
Sheath colour
Black
Lead free
Yes
Conductor shape
Circular

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV
Dielectric strength
3.5 kV
Time of application Dielectric strength core to screen DC
5 min.

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Excellent

Usage characteristics

Usage characteristics

Flame retardant
IEC 60332-1-2; FT1
Oil resistance
Good
Maximum operating temperature
80 °C
Overload maximum core temperature
100 °C
Short-circuit max. conductor temperature
160 °C

Resources

Resources

Documentation

xlsx — 0 B

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close