WIRE/OF 200° 26 AWG

Description

Description

Standards

  • Product
    ASTM B 1
  • National
    NEMA MW 73-C

 

Application:

In the windings of electrical equipment operating temperature of around 200 ° C, for traction motors, transformers. In any equipment subject to severe conditions of moisture and heat.

 

Construction:

Wire: Hard copper.

Insulated: Enamel polyester (amide) (imide) overcoated with Polyamideimide.

 

Main characteristics:

Excellent thermal stability with good electrical and mechanical characteristics. Resistance to abrasion. Both copper and enamel have resistance to handling and easily rolled. Good adhesion between copper and enamel.

Gauge:

From 26 AWG to 12 AWG.

Packing:

In plastic reels DIN type.

 

International standards

ASTM B 1: Hard-drawn copper wire.

ANSI/NEMA MW 73-C: Magnet wire - polyester (amide)(imide) Overcoated with Polyamideimide for Hermetic Applications (Heavy, Triple, Quad).

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Hard copper
Enamel type
Polyesterimide - polyamide/imide

Dimensional characteristics

Dimensional characteristics

Conductor cross-section (AWG/KCMIL)
26
Wire diameter
0.4 mm
Outer Diameter
0.46 mm
Approximate weight
1 kg/km

Mechanical characteristics

Mechanical characteristics

Elongation
27 %

Usage characteristics

Usage characteristics

Chemical resistance
Good
Reference
01
Thermal class (base coat)
200

Resources

Resources

Dealer locator

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close